Li/SOCl2 Battery

  • Item:: ER (Li/SOCl2) Battery 3.6V
  • Brief:: 1.High energy density (620Wh/Kg); 2. High open circuit voltage (3.66V for single cell); 3. Wide range of operating temperature (-55°C~+85°C).
  • Publish time:2020-02-04 15:20:25

    High energy density (620Wh/Kg)

    ER batteries' shapes

    Button,cylindrical

    and square shapes are available for your choice.

    Application:
    CMOS memory chips for PC, office automation devices, remote data logging and data acquisition systems, medical instruments, water or gas gauges, security and alarm systems pulse-/event-counters, various industrial clocks, high temperature systems etc.
    Feature:
    (1) high energy density up to 420WH/Kg(800WH/dm3).
    (2) High operation voltage, 3.3V~3.6V upon loading resistance. 
    (3) Long storage life, less than 2% of self-discharging rate per year, could be stored for 10~15 year at room temperature.
    (4) Non-magnetic stainless steel case, hermetically sealed. Be safe for transportation and general shock. No leakage problem.
    Due to the characteristics of Li-SOCl2 battery, 
    there are three basic type:
    A. ENERGY TYPE BATTERY
    (1). Bobbin Type, high capacity, shelf life is ten years;
    (2). Wide operating temperature range, -55 °C~+85°C.
    (2). Smooth voltage level, 90% capacity could be outputted at high level.

     

    Type

    Nominal
    capacity

    Nominal
    voltage

    Operating current
    mA(max)

    Standard
    discharge

    Cut off
    voltage

    Dimension
    mm(max)

    weight

    GB

    IEC

    mAh

    V

    continuous

    pulse

    current mA

    V

    dia.

    H

    g

    .

    1200

    9.0

    35

    100

    0.5

    5.4

    48.8*26*16.9

    40

    1/2AAA

    400

    3.6

    5

    10

    0.5

    2.0

    10.4

    25.0

    3.8

    AAA

    750

    3.6

    15

    50

    1.0

    2.0

    10.3

    45.0

    8

    ER14200

     

    600

    3.6

    10

    15

    1.0

    2.0

    14.5

    20.0

    8

    1/2AA

    1200

    3.6

    25

    100

    1.0

    2.0

    14.5

    25.0

    10

    2/3AA

    1650

    3.6

    50

    100

    1.0

    2.0

    14.5

    33.5

    13

    AA

    2400

    3.6

    70

    150

    1.0

    2.0

    14.5

    50.5

    19

    ER17250

     

    1000

    3.6

    100

    200

    1.0

    2.0

    17.0

    25.0

    12

    2/3A

    1900

    3.6

    100

    200

    0.5

    2.0

    17.0

    33.5

    19

    ER17450

     

    3000

    3.6

    100

    200

    3.0

    2.0

    17.0

    45.0

    25

    A

    3400

    3.6

    120

    200

    2.0

    2.0

    17.0

    50.5

    27

     

    4000

    3.6

    100

    200

    3.0

    2.0

    18.5

    50.5

    31

    ER26250

    1/2C

    3000

    3.6

    30

    200

    1.0

    2.0

    26.2

    25.0

    26

    C

    8500

    3.6

    150

    300

    2.0

    2.0

    26.2

    50.0

    55

    ER261020

    CC

    15000

    3.6

    100

    400

    1.0

    2.0

    26.2

    102.0

    100

    D

    19000

    3.6

    230

    400

    2.0

    2.0

    34.2

    61.5

    102

    ER341245

    DD

    36000

    3.6

    200

    400

    3.0

    2.0

    34.0

    124.5

    200

    ER10280

     

    450

    3.6

    10

    20

    0.5

    2.0

    10.4

    28.0

    5


    B. POWER TYPE BATTERY
    (1) high discharge rate, and you can always consult our engineer for even higher discharge rate;
    (2) have large continuous or pulse current and large power output for over five years 
    (3) lower resistance, smooth voltage level.

     

     

    Type

    Nominal
    capacity

    Nominal
    voltage

    Operating current
    mA

    Standard
    discharge
    current mA

    Cut off
    voltage

    Dimension
    mm

    Weight

    GB

    IEC

    mAh

    V

    continuous

    pulse

    current mA

    V

    dia.

    H

    g

    1/2AA

    750

    3.6

    200

    400

    1

    2.0

    14.5

    25.0

    10

    2/3AA

    1350

    3.6

    200

    500

    2

    2.0

    14.5

    33.5

    13

    AA

    1800

    3.6

    500

    1000

    3

    2.0

    14.5

    50.5

    19

    2/3A

    1700

    3.6

    400

    1000

    3

    2.0

    17.0

    33.5

    19

    A

    2800

    3.6

    1000

    2000

    10

    2.0

    17.5

    50.5

    30


    3200

    3.6

    1000

    2000

    5

    2.0

    18.5

    50.5

    32

    C

    5800

    3.6

    1000

    2000

    10

    2.0

    18.5

    50.5

    56

    D

    14000

    3.6

    2000

    3000

    15

    2.0

    34.2

    61.5

    108


    28000

    3.6

    2000

    5000

    50

    2.5

    48.0

    66

    284

     

    Available Tags/pin/Terminations for ER Batteries(click)Markyn Batteries

     

     

    C. Hi-temperature ER batteries and battery packs for Oil and Gas

     Ccdsfadsadksal;fdjsa;lfjdksa;fjdsa;lfdj

    Type

    Nominal
    capacity

    Nominal
    voltage

    Operating current
    mA(max)

    Standard
    discharge
    current mA

    Cut off
    voltage

    Dimension
    mm(max)

    Weight

    GB

    IEC

    mAh

    V

    continuous

    pulse

    current mA

    V

    dia.

    H

    g


    AAA

    600

    3.6

    50

    100

    10

    2.0

    10.2

    45.0

    9

    1/2AA

    600

    3.6

    50

    100

    10

    2.0

    14.5

    25.0

    10

    2/3AA

    1000

    3.6

    50

    100

    50

    2.0

    14.5

    33.5

    14

    ER17335S


    1500

    3.6

    100

    200

    1

    2.0

    17.0

    33.5

    20


    3200

    3.6

    1000

    2000

    100

    2.0

    18.8

    50.5

    32

    C

    6000

    3.6

    200

    300

    4

    2.0

    26.2

    50.0

    52

    D

    12500

    3.6

    200

    400

    10

    2.0

    34.0

    61.5

    100

    DD

    22000

    3.6

    300

    600

    100

    2.0

    34.0

    124.5

    200

     

     ER High Temperature Packs

    Items

    Voltage
    (V)

    Capacity
    (Ah)

    Dimensions
    (mm)

    Max. Continuous
    (mA)

    Working Temperature()

    Gamma Battery packs

    14.4

    10.0

    Ø38×L:369

    800

    -40--165

    Geolink D Battery Packs

    36

    11.0

    Ø37.8×L:785

    300

    -40--165

    MWD-BT PACKS

    28.8-29.2

    28.0

    Ø37.5

    1200

    -40--165

    HL PACKS

    28.8-29.2

    27.0

    Ø37.5

    1200

    -40--165

    Geolink DD Packs

    18

    27.0

    Ø37.8×L:785

    800

    -40--165

    SQ Packs

    28.8-29.2

    27.0

    Ø37.3

    800

    -40--165

    SW PACKS

    25.2

    27.0

    Ø35.0

    800

    -40--165

    GE-MWD-QDT PACKS

    28.8-29.2

    27.0

    Ø37.5

    1200

    -40--165

    APS-MWD PACKS

    36

    27.0

    Ø37.0

    1200

    -40--165

    FE PACKS

    21.6×3

    8.5

    L:192×3

    300

    -40--165

    PLM PACKS

    35.8-36.3

    29.5

    Ø37.5

    1200

    -40--165

     Coal-bed methane rotation Gamma Packs

    29

    27.0

    Ø36.3×L:1250

    500

    -40--165

    Docking battery

    57.6

    27.5

    Ø36×L:2712

    500

    -40--165

    CBM focusing Gamma battery pack

    28.8

    10.0

    Ø36.3×L:655

    300

    -40--165

    Coal-bed methane emission battery 

    14.4

    80.0

    Ø36.3×L:1800

    500

    -40--165

    CPR Battery Packs

    28.8-29.2

    40.0

    Ø53.0×L:775

    1200

    -40--165

     

    Customer request form Markyn Batteries
     

    Li-SOCl2 battery Caution :
    (1) Do not make the battery short-circuit and do not try to charge it.
    (2) Do not over-discharge , press or burn the battery.
    (3) The battery should be removed from the instrument on time when finishing discharging.
    (4) The battery should be buried deeply in earth .
    (5) Do not try to solder directly on battery.
    (6) The high temperature type Li-soc12 battery can not be used at environment above +160

     

     

    SPECIFICATIONS OF HIGH TEMPERATURE ER(LiSOCl2) BATTERY


              Type

    Nominal
    capacity

    Nominal
    voltage

    Operating current
    mA(max)

    Standard
    discharge
    current mA

    Cut off
    voltage

    Dimension
    mm(max)

    Weight

    GB

    IEC

    mAh

    V

    continuous

    pulse

    current mA

    V

    dia.

    H

    g

    1/2AA

    600

    3.6

    50

    100

    10

    2.0

    14.5

    25.0

    10

    2/3AA

    1000

    3.6

    50

    100

    50

    2.0

    14.5

    33.5

    14

    ER17335S


    1500

    3.6

    100

    200

    1

    2.0

    17.0

    33.5

    20


    3200

    3.6

    1000

    2000

    100

    2.0

    18.8

    50.5

    32

    C

    6000

    3.6

    200

    300

    4

    2.0

    26.2

    50.0

    52

    CC

    9500

    3.6

    100

    200

    100

    2.0

    24.5

    102

    102

    D

    12500

    3.6

    200

    400

    10

    2.0

    34.0

    61.5

    100

    DD

    22000

    3.6

    300

    600

    100

    2.0

    34.0

    124.5

    200


    SPECS OF HI-TEMPERATURE BATTERY PACKS & THEIR APPLICATIONS

                     Items

    Voltage
    (V)

    Capacity
    (Ah)

    Dimensions
    (mm)

    Max. Continuous
    (mA)

    Working Temperature()

    Gamma Battery packs

    14.4

    10.0

    Ø38×L:369

    800

    -40--165

    Geolink D Battery Packs

    36

    11.0

    Ø37.8×L:785

    300

    -40--165

    MWD-BT PACKS

    28.8-29.2

    28.0

    Ø37.5

    1200

    -40--165

    HL PACKS

    28.8-29.2

    27.0

    Ø37.5

    1200

    -40--165

    Geolink DD Packs

    18

    27.0

    Ø37.8×L:785

    800

    -40--165

    SQ Packs

    28.8-29.2

    27.0

    Ø37.3

    800

    -40--165

    SW PACKS

    25.2

    27.0

    Ø35.0

    800

    -40--165

    GE-MWD-QDT PACKS

    28.8-29.2

    27.0

    Ø37.5

    1200

    -40--165

    APS-MWD PACKS

    36

    27.0

    Ø37.0

    1200

    -40--165

    FE PACKS

    21.6×3

    8.5

    L:192×3

    300

    -40--165

    PLM PACKS

    35.8-36.3

    29.5

    Ø37.5

    1200

    -40--165

     Coal-bed methane rotation Gamma Packs

    29

    27.0

    Ø36.3×L:1250

    500

    -40--165

    Docking battery

    57.6

    27.5

    Ø36×L:2712

    500

    -40--165

    CBM focusing Gamma battery pack

    28.8

    10.0

    Ø36.3×L:655

    300

    -40--165

    Coal-bed methane emission battery 

    14.4

    80.0

    Ø36.3×L:1800

    500

    -40--165

    CPR Battery Packs

    28.8-29.2

    40.0

    Ø53.0×L:775

    1200

    -40--165

     

    1. Since 1942

    2. Father of Chinese primary ER, WR and CR lithium batteries;

    3. 71 years' working experiences accumulated;

    4. Complete automatic production line;

    5. Old cusotmers include TI, Flectronics Singapore HQ, Midea Group, etc.
    6. 16 years' export to customers around the world;

    7. Production Capacity, 2 million ER14250 per day.

        ......


    Li-SOCl2 battery Caution :
    (1) Do not make the battery short-circuit and do not try to charge it.
    (2) Do not over-discharge , press or burn the battery.
    (3) The battery should be removed from the instrument on time when finishing discharging.
    (4) The battery should be buried deeply in earth .
    (5) Do not try to solder directly on battery.
    (6) The high temperature type Li-soc12 battery can not be used at environment above +160

     

    ER Battery Production Brief Workflow

     

    1.Cathode Mixer
    Mixing Acetylene Black with Solvent and Bonding Chemicals to Form Cathode.  Automatically Controlled to Ensure Stable Quality and Safety.

     

    Markyn Batteries

     

    2.Oven
    Easy to Operate with Automatic Alarm Device for Safety.  Automatically Controlled to Ensure Quality.

     

    Markyn Batteries

     
    3.Cathode Molding System
    Forming the Cathode into Circular Balls with Preset Size.  Automatically Controlled System to Ensure Cathode Density.

     

    Markyn Batteries

     
    4.Automatic Nickel Tab Welding Machine
    Automatic Spot Welding Nickel Tabs on Both Ends of Battery to Ensure the Quality of Welding and Precise Locations.
     
    Markyn Batteries
     
    5.Dehumidifier System
    Four High Quality Dehumidifiers Generating Large Flow of Dry Air to Reduce Dew Point of Air in Battery Assembling Rooms and Chambers Below -40℃ Constantly.
     
    Markyn Batteries
     
    6.Automatic Assembling Lines
    Automatically Positioning Parts and Materials and Assembling Them Properly Together.  Using Automatic conveyers to Connect Assembling Steps. Substantially Reducing Labor Required and Human Errors. 
     
    Markyn Batteries
     
    7.Anode Assemble Machine
    Automatically Rolling and  Pressing Lithium Strip into Battery Shell
     
    Markyn Batteries
     
    8.Separator Assemble Machine
    Automatically Installing Separators on Bottom and Side of Battery Shell
     
    Markyn Batteries
     
    9.Cathode Assemble Machine
    Automatically Putting Preset Quantity of Ball Shape Cathode into Battery Shell
     
    Markyn Batteries
     
    10.Cap Assemble Machine
    Automatically Pressing Battery Cap Firmly Sealed with Battery Shell
     
    Markyn Batteries
     
    11.Internal Shorting Testing Machine
    Automatically Testing Internal Resistance After Cap Installed and Rejecting Failed Battery
     
    Markyn Batteries
     
    12.Epoxy Applying Machine
    Automatically Applying Epoxy on Battery Cap to Prevent Shorting
     
    Markyn Batteries
     
    13.Polishing Machine
    Automatically Polishing Both Positive and Negative Electrodes to Make Tab Welding More Firmly
     
    Markyn Batteries
     
    14.Sleeve Installation System
    Automatically Feeding Sleeve and Wrapping Properly Around Battery.  Shrinking Battery Sleeve Through Hot Air Chamber.
     
    Markyn Batteries
     

    15.Automatic Testing Machine

    Automatically Testing Open Circuit Voltage and Voltage with Load and Rejecting failed Battery

     
    Markyn Batteries
     
    16.Automatic Tab Welding Machine
    Automatically Spot Welding Nickel Tabs on Both Ends of Battery.  Measuring OCV after Tabs Installed.  Tracking and Recording Entire Process for Inspection.
    
    Markyn Batteries
     
    17.ER Battery Finishing & Packing Lines
    Installing Battery Connectors & Packing Batteries According to Customer' s requests.  Inspecting Final Products.
     
    Markyn Batteries
     
    18.Battery Aging Room with Controlled Temperature 
    Storing Batteries in Rooms with Temperature Controlled Under 28℃ Yearly Long.
     
    Markyn Batteries
     
    19.Battery Testing System
    Testing Battery OCV, Voltage with Load and Capacity for Constant Currents & Constant Resistances. Simultaneously  Testing Over 2,00 Batteries.
     
    Markyn Batteries
     
    20.Fourier Transform Infrared Spectroscopy
    Accurately  Measuring Water Containing in Electrolyte
     
    Markyn Batteries
     
    21.Environmental Testing Room
    Testing Battery According to Military Specifications Including Vibration, Shock, Temperature Cycling, High Humidity, Low Pressure….
     
    Markyn Batteries

    Customer request form Markyn Batteries

    Li-SOCl2 battery Caution :
    (1) Do not make the battery short-circuit and do not try to charge it.
    (2) Do not over-discharge , press or burn the battery.
    (3) The battery should be removed from the instrument on time when finishing discharging.
    (4) The battery should be buried deeply in earth .
    (5) Do not try to solder directly on battery.
    (6) The high temperature type Li-soc12 battery can not be used at environment above +160

    
    Home